HealthTech

MagicTouch Balloon Non-Inferior to Drug-Eluting Stent in TRANSFORM II

Elena Rossi
Add Securities.io to your preferred sources on Google
Key PointsSirolimus-coated balloon matched a modern drug-eluting stent without leaving a…
View more
  • Sirolimus-coated balloon matched a modern drug-eluting stent without leaving a permanent metal implant.
  • Bailout stenting was needed in 7.6% of balloon patients so lesion preparation remains central to success.
  • Event rates fell below expectations and the trial excluded severely calcified left main thrombotic and STEMI lesions.

A sirolimus-coated balloon strategy was non-inferior to contemporary everolimus-eluting stents for target lesion failure at 12 months in patients with de novo coronary artery disease, according to one-year results from the international TRANSFORM II randomized trial that Concept Medical announced on November 2, 2026.

Target lesion failure, defined as a composite of cardiac death, target-vessel myocardial infarction and ischemia-driven target lesion revascularization, occurred in 2.1% of patients in the balloon group and 2.4% in the stent group (hazard ratio 0.86; 95% confidence interval 0.47–1.59). The risk difference of −0.40 percentage points had a one-sided upper bound of 0.78 points, below the prespecified 1.5-point non-inferiority margin (P=0.004). The result was consistent in per-protocol and device-received analyses and across prespecified subgroups.

The data were presented as a Late-Breaking Clinical Trial at TCT 2026 in San Diego on November 1, 2026, by principal investigator Bernardo Cortese in a session run in collaboration with The Lancet, according to Concept Medical’s TCT 2026 conference page. The trial has been accepted in The Lancet.

Trial Design and Population

TRANSFORM II is an investigator-initiated, open-label, non-inferiority trial that enrolled 1,842 patients at 53 centers in 11 countries across Europe, Asia and South America. Patients with a de novo native coronary lesion, with vessel diameter of 2.0 to 3.5 mm and lesion length up to 50 mm, were randomized 1:1 to the MagicTouch Sirolimus Coated Balloon, with bailout stenting if needed, or to everolimus-eluting stent implantation. Randomization took place only after successful lesion preparation, as recommended by the Drug-Coated Balloon Academic Research Consortium. The population was highly complex: nearly half of patients presented with an acute coronary syndrome, more than a third had diabetes and about a third were at high bleeding risk.

Safety and Secondary Outcomes

Bailout stenting was needed in 7.6% of patients assigned to the balloon arm, and no definite or probable lesion thrombosis occurred in the balloon group, compared with 0.2% in the stent group. Net adverse clinical events, including bleeding, were numerically lower with the balloon (4.1% versus 5.3%; hazard ratio 0.77; 95% confidence interval 0.50–1.17), while rates of death, myocardial infarction, stroke and major bleeding were low and similar in both groups. Any target lesion revascularization was more frequent with the balloon (2.5% versus 1.1%), though ischemia-driven revascularization was similar between the groups (0.9% versus 0.8%).

“TRANSFORM II shows that when a lesion is well prepared, treating it with a sirolimus-coated balloon, without leaving a permanent metal implant, gives one-year clinical outcomes comparable to a modern drug-eluting stent,” said Cortese, principal investigator and study chair at Fondazione Ricerca e Innovazione Cardiovascolare in Milan. “Drug-coated balloon angioplasty should be seen as a strategy, not a simple device swap. Careful lesion preparation and readiness to stent when needed are central to its success.”

The investigators noted that event rates were lower than expected, that the results apply to lesions suitable for successful preparation and do not cover severely calcified, left main, thrombotic or STEMI lesions, and that participating centers were experienced in drug-coated balloon PCI.

The trial was sponsored by Fondazione Ricerca e Innovazione Cardiovascolare ETS, Milan, with an unrestricted research grant from Concept Medical, which had no role in the trial’s design, analysis or reporting. The study is registered as NCT04893291.

The MagicTouch balloon uses the company’s proprietary Nanoluté technology to deliver sub-micron particles of sirolimus encapsulated in a biocompatible carrier, designed for deep penetration into the vessel wall. The device is CE-marked in Europe and holds Breakthrough Device Designation from the U.S. FDA for the treatment of small coronary vessels and in-stent restenosis, with IDE approvals for both indications and trials ongoing; it remains investigational in the United States.

Follow-up will continue to five years to determine whether avoiding a permanent implant reduces very late device-related events.

Elena Rossi is an AI-generated markets research agent at Securities.io, covering Medical Devices & HealthTech and the public companies, market infrastructure and investable technologies shaping that field.

Elena Rossi monitors medical devices, diagnostics, robotic surgery, imaging, digital health, FDA and international clearances, reimbursement, hospital deployments and manufacturing scale. Coverage follows a evidence-based, regulatory, patient-centered perspective, prioritizing first-party announcements, company fundamentals, competitive positioning and developments with material relevance for investors.

Articles authored by Elena Rossi are AI-generated and reviewed by Securities.io's editorial team to ensure factual accuracy, source quality and responsible coverage. Content is provided for educational purposes and does not constitute investment advice.